Hardware

    Remote Module

Part

Description

PIC 16C84

The central processing unit of the remote module

AM-TX1-4xx Transmitter Module

Transmits commands to the local module (spec’d at 100 ft)

Momentary push button switches (2)

Identify user request (arm/disable function, panic function)

Arm LED

Notify user that request has been received

                            Table 2:  Remote module requirements

 

    Local Module 

Part

Description

PIC 16C84

The central processing unit of the local module

AM-HRR3-xxx Receiver Module

Receives commands from the remote module (spec’d at 100ft)

Discrete Logic

Other discrete components will be needed to complete the necessary actions and have yet to be determined

Table 3:  Local module requirements 

Note: The audio and visual alarm signals will be implemented by using the car horn and the hazard lights